APC BX850M
SKU: CS4805264MPN: BX850MUPC/EAN: 731304331797
APC Back-UPS 850, Compact Tower, 850VA, 120V, AVR, LCD, 8 NEMA outlets (4 surge)

Contact us for pricing and availability
Product Details
APC Back-UPS 850, Compact Tower, 850VA, 120V, AVR, LCD, 8 NEMA outlets (4 surge)
Attributes
| Sena Acoustic Level | 45 dBA |
| Sena Alarm | alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
| Sena Ambient Air Temperature For Operation | 0-40 °C |
| Sena Ambient Air Temperature For Storage | -15-45 °C |
| Sena Battery Charger Power | 7 W rated |
| Sena Battery Curve | C |
| Sena Battery Life | 3-5 year(s) |
| Sena Battery Recharge Time | 12 h |
| Sena Battery Type | lead-acid battery |
| Sena Control Panel | multifunction LCD status and control console |
| Sena Curve Equation | efficiency |
| Sena Curve Fixed Loss | 0.0048000002279878 |
| Sena Curve Load Maximum | 1.0000 |
| Sena Curve Load Minimum | 0.0099999997764826 |
| Sena Curve Square Loss | 0.0043000001460314 |
| Sena Curve Test Cond Id | Curve fit of data measured in accordance with the US DOE Test Procedure for Uninterruptible Power Supplies. All measurements taken in normal mode(s), at typical environmental conditions, with 120V/60Hz electrical input and balanced resistive load (PF = 1. |
| Sena Curve X Axis Maximum | 1.0000 |
| Sena Curve X Axis Title | load |
| Sena Curve X Axis Units | percentage |
| Sena Curve Y Axis Maximum | 1.0000 |
| Sena Curve Y Axis Minimum | 0.5000 |
| Sena Curve Y Axis Title | efficiency |
| Sena Curve Y Axis Units | percentage |
| Sena Data Line Protection | RJ45 network line - 10/100/1000 Base-T Ethernet# #coaxial cable for CATV/SATV/modem/audio-video |
| Sena Equipment Protection Policy | lifetime : $250000 |
| Sena Graph Display | 1.0000 |
| Sena Heat Dissipation | 48.5 Btu/h |
| Sena Input Voltage | 120 V |
| Sena Input Voltage 1 | 120 V |
| Sena Input Voltage Limits | 88…139 V |
| Sena Maximum Configurable Power In Va | 850 VA |
| Sena Maximum Configurable Power In W | 510 W |
| Sena Maximum Output Current | 15 A |
| Sena Mounting Mode | not rack-mountable |
| Sena Mounting Preference | no preference |
| Sena Nb Of Power Socket Outlets | 4 NEMA 5-15R 4 NEMA 5-15R surge |
| Sena Network Frequency | 60 Hz ± 3 Hz |
| Sena Noise Suppression | full time multi-pole noise filtering : 5% of IEEE surge let-through : zero clamping response time: instantaneous |
| Sena Number Of Battery Replacement Quantity | 1.0000 |
| Sena Number Of Tare Power | 16 W |
| Sena Operating Altitude | 0…10000 ft |
| Sena Output Frequency | 60 Hz sync to mains |
| Sena Output Voltage | 120 V |
| Sena Output Voltage 1 | 120 V |
| Sena Plug Standard | NEMA 5-15P |
| Sena Product Certifications | California Energy Commission (CEC)# #ENERGY STAR V2.0 (USA)# #TUV C-US certified |
| Sena Rated Power In Va | 850 VA |
| Sena Rated Power In W | 510 W |
| Sena Redundant | No |
| Sena Relative Humidity | 0-95 % |
| Sena Show Note Op Temperature | No |
| Sena Standards | FCC part 15 class B |
| Sena Storage Altitude | 0-50000 ft |
| Sena Storage Relative Humidity | 0-95 % |
| Sena Surge Energy Rate | 1103 J |
| Sena Switching Current Capacity | 15 A |
| Sena Transfer Time | 8 ms typical : 10 ms maximum |
| Sena Ups Size | WS |
| Sena Ups Type | line interactive |
| Sena Usb Compatible | No |
| Sena Wave Type | stepped approximation to a sinewave |
Specifications
| SKU | CS4805264 |
|---|---|
| MPN | BX850M |
| UPC/EAN | 731304331797 |