APC BE850G2
SKU: CS3753220MPN: BE850G2UPC/EAN: 731304413592
APC Back-UPS 850VA, 120V, 2 USB charging ports, 9 NEMA outlets (3 surge)

Contact us for pricing and availability
Product Details
Back-UPS 850VA, 2 USB charging ports- Output power capacity : 450Watts / 850VA - Max Configurable Power (Watts) : 450Watts / 850VA - Nominal Output Voltage : 120V - Output Frequency (sync to mains) : 50/60Hz +/- 3 Hz - Nominal Input Voltage : 120V - Input frequency : 50/60 Hz +/- 3 Hz (auto sensing) - Input Connections : NEMA 5-15P - Cord Length : 5ft (1.52meters) - Input voltage range for main operations : 92 - 139V
Attributes
| Sena Acoustic Level | 45 dBA |
| Sena Alarm | alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
| Sena Ambient Air Temperature For Operation | 0-40 °C |
| Sena Ambient Air Temperature For Storage | -15-45 °C |
| Sena Battery Charger Power | 13 W rated |
| Sena Battery Curve | B |
| Sena Battery Graph Comments | This graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several v |
| Sena Battery Life | 2-5 year(s) |
| Sena Battery Recharge Time | 8 h |
| Sena Battery Type | lead-acid battery |
| Sena Control Panel | LED status display with on line : on battery : replace battery and building wiring fault |
| Sena Curve Equation | efficiency |
| Sena Curve Fixed Loss | 0.0065000001341105 |
| Sena Curve Load Maximum | 1.0000 |
| Sena Curve Load Minimum | 0.0099999997764826 |
| Sena Curve Square Loss | 0.0060000000521541 |
| Sena Curve Test Cond Id | Curve fit of data measured in accordance with the US DOE Test Procedure for Uninterruptible Power Supplies. All measurements taken in normal mode(s), at typical environmental conditions, with 120V/60Hz electrical input and balanced resistive load (PF = 1. |
| Sena Curve X Axis Maximum | 1.0000 |
| Sena Curve X Axis Title | load |
| Sena Curve X Axis Units | percentage |
| Sena Curve Y Axis Maximum | 1.0000 |
| Sena Curve Y Axis Minimum | 0.5000 |
| Sena Curve Y Axis Title | efficiency |
| Sena Curve Y Axis Units | percentage |
| Sena Equipment Protection Policy | lifetime : $75000 |
| Sena Graph Display | 1.0000 |
| Sena Input Voltage | 120 V |
| Sena Input Voltage 1 | 120 V |
| Sena Input Voltage Limits | 92…139 V |
| Sena Maximum Configurable Power In Va | 850 VA |
| Sena Maximum Configurable Power In W | 450 W |
| Sena Mounting Mode | not rack-mountable |
| Sena Mounting Preference | no preference |
| Sena Nb Of Power Socket Outlets | 3 NEMA 5-15R surge 6 NEMA 5-15R |
| Sena Network Frequency | 50/60 Hz ± 3 Hz auto-sensing |
| Sena Number Of Cables | 1.0000 |
| Sena Number Of Tare Power | 7 W |
| Sena Operating Altitude | 0…10000 ft |
| Sena Output Frequency | 50/60 Hz ± 3 Hz sync to mains |
| Sena Output Voltage | 120 V |
| Sena Output Voltage 1 | 120 V |
| Sena Plug Standard | NEMA 5-15P |
| Sena Product Certifications | California Energy Commission (CEC)# #cTUVus |
| Sena Provided Equipment | USB cable user manual |
| Sena Provided Equipment 1 | USB cable user manual |
| Sena Provided Equipment 2 | USB cable user manual |
| Sena Rated Power In Va | 850 VA |
| Sena Rated Power In W | 450 W |
| Sena Redundant | No |
| Sena Relative Humidity | 0-95 % |
| Sena Show Note Op Temperature | No |
| Sena Standards | CSA C22.2 No 107.3# #FCC part 15 class B# #UL 1778 |
| Sena Storage Altitude | 0-50000 ft |
| Sena Storage Relative Humidity | 10-90 % |
| Sena Surge Energy Rate | 354 J |
| Sena Transfer Time | 6 ms typical : 10 ms maximum |
| Sena Ups Size | WS |
| Sena Ups Type | standby |
| Sena Usb Compatible | No |
| Sena Wave Type | stepped approximation to a sinewave |
Specifications
| SKU | CS3753220 |
|---|---|
| MPN | BE850G2 |
| UPC/EAN | 731304413592 |











