APC BR1500G
SKU: CS2528378MPN: BR1500GUPC/EAN: 731304268772
APC Back-UPS Pro, 1500VA/865W, Tower, 120V, 10x NEMA 5-15R outlets, AVR, LCD, User Replaceable Battery

Contact us for pricing and availability
Documents
Product Details
APC Power Saving Back-UPS Pro 1500
APC Back-UPS Pro,865 Watts /1500 VA,Input 120V /Output 120V, Interface Port USB, Extended runtime model
Includes: CD with software, USB cable, User Manual
Attributes
| Sena Acoustic Level | 45 dBA |
| Sena Alarm | alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
| Sena Ambient Air Temperature For Operation | 0-40 °C |
| Sena Ambient Air Temperature For Storage | -15-45 °C |
| Sena Battery Capacity | 9.0 Ah |
| Sena Battery Charger Power | 23 W rated |
| Sena Battery Curve | C |
| Sena Battery Graph Comments | This graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several v |
| Sena Battery Life | 3-5 year(s) |
| Sena Battery Option | BR24BP 1 518 VAh BR24BPG 1 518 VAh |
| Sena Battery Recharge Time | 8 h |
| Sena Battery Type | lead-acid battery |
| Sena Battery Voltage | 24 V |
| Sena Control Panel | multifunction LCD status and control console |
| Sena Curve Equation | efficiency |
| Sena Curve Fixed Loss | 0.0041000000201166 |
| Sena Curve Load Maximum | 1.0000 |
| Sena Curve Load Minimum | 0.0099999997764826 |
| Sena Curve Square Loss | 0.0068999999202788 |
| Sena Curve Test Cond Id | Curve fit of data measured in accordance with the US DOE Test Procedure for Uninterruptible Power Supplies. All measurements taken in normal mode(s), at typical environmental conditions, with 120V/60Hz electrical input and balanced resistive load (PF = 1. |
| Sena Curve X Axis Maximum | 1.0000 |
| Sena Curve X Axis Title | load |
| Sena Curve X Axis Units | percentage |
| Sena Curve Y Axis Maximum | 1.0000 |
| Sena Curve Y Axis Minimum | 0.5000 |
| Sena Curve Y Axis Title | efficiency |
| Sena Curve Y Axis Units | percentage |
| Sena Data Line Protection | cable modem/video protection# #RJ45 network line - 10/100/1000 Base-T Ethernet |
| Sena Equipment Protection Policy | lifetime : $150000 |
| Sena Graph Display | 1.0000 |
| Sena Input Voltage | 120 V |
| Sena Input Voltage 1 | 120 V |
| Sena Let Through Voltage Rating | 300 V |
| Sena Maximum Configurable Power In Va | 1500 VA |
| Sena Maximum Configurable Power In W | 865 W |
| Sena Mounting Mode | not rack-mountable |
| Sena Mounting Preference | no preference |
| Sena Nb Of Power Socket Outlets | 5 NEMA 5-15R 5 NEMA 5-15R surge |
| Sena Network Frequency | 50/60 Hz ± 3 Hz auto-sensing |
| Sena Noise Suppression | full time multi-pole noise filtering : 5% of IEEE surge let-through : zero clamping response time: instantaneous |
| Sena Number Of Battery Filled Slots | 1.0000 |
| Sena Number Of Battery Replacement Quantity | 1.0000 |
| Sena Number Of Tare Power | 13 W |
| Sena Operating Altitude | 0…30000 ft |
| Sena Output Frequency | 50/60 Hz ± 3 Hz sync to mains |
| Sena Output Voltage | 120 V |
| Sena Output Voltage 1 | 120 V |
| Sena Performance Multiplier | 1.0000 |
| Sena Plug Standard | NEMA 5-15P |
| Sena Product Certifications | NOM# #TÜV# #ENERGY STAR V2.0 (USA) |
| Sena Rated Power In Va | 1500 VA |
| Sena Rated Power In W | 865 W |
| Sena Redundant | No |
| Sena Relative Humidity | 0-95 % |
| Sena Show Note Op Temperature | No |
| Sena Standards | FCC part 15 class B# #UL 1778 |
| Sena Storage Altitude | 0-50000 ft |
| Sena Storage Relative Humidity | 0-95 % |
| Sena Surge Energy Rate | 354 J |
| Sena Transfer Time | 8 ms typical : 12 ms maximum |
| Sena Ups Size | WS |
| Sena Ups Type | line interactive |
| Sena Usb Compatible | Yes |
| Sena Value Multiplier | 1.0000 |
| Sena Wave Type | stepped approximation to a sinewave |
Specifications
| SKU | CS2528378 |
|---|---|
| MPN | BR1500G |
| UPC/EAN | 731304268772 |