ACI QTS-61110X-S000000
SKU: CS6287673MPN: QTS-61110X-S000000Alternate Part #: 136150
Toxic Gas Sensor, Hydrogen Sulphide, Industrial 316 S.S., (NEMA 4X, 7, 9)

Contact us for pricing and availability
Product Details
Toxic Gas Sensor, Hydrogen Sulphide, Industrial 316 S.S., (NEMA 4X, 7, 9)
Product Configuration
| Gas Type | Hydrogen Sulphide |
|---|
Product Family Specifications
| Accuracy | +/- 2.5% of Reading |
|---|---|
| Sensor Life | 2 to 3 years, typical |
| Sensor Type | Electrochemical, non-consuming |
| Repeatability | +/- 1% of Reading |
| Response Time | T90: \< 60 Seconds, typical |
| Output Signals | 4-20 mA (2-Wire, Loop Powered) |
| Product Weight | Industrial “E”/“S” Enclosures: 5.00 lbs (2.27kg) Commercial “C”/“D”/“N” Enclosures: 2.00 lbs (0.91kg) |
| Unit Shelf Life | 6 Months from date of purchase (Must be installed and operational) |
| Agency Approvals | RoHS, CSA-4828-02 (CSA File #: 088890 0 000 for Industrial Enclosure Options Only) |
| Factory Set Range | See Gas Sensor Selection \& Specification Table on back of data sheet |
| Product Dimensions | Commercial “C” Enclosure: 6.60” (167.64 mm) x 4.23” (107.44 mm) x 2.60” (66.04 mm) Commercial “D”\& “N” Enclosure: 6.60” (167.64 mm) x 4.23” (107.44 mm) x 3.70” (93.98 mm) Industrial “E”\& “S” Enclosure: 10.70” (271.78 mm) x 5.71” (145.04 mm) x 4.25” (107.95 mm) |
| RFI/EMI Protection | 4.0 Watts @ 1m (3.28 ft) Radiated |
| Operating Environment | Indoor Use only |
| Connections | Wire Size | Screw Terminal Blocks, 16 to 24 AWG (0.51 to 1.30 mm) Shielded Twisted Pair |
| Maximum Load (@ 24 VDC) | 600 Ohms |
| Recommended Maintenance | Accuracy \& Bump test every 3 to 6 months or as required by Code | Replace sensor as need |
| Operating Humidity Range | 0 to 90% RH, non-condensing (Continuous); 0 to 95% RH, non-condensing (Intermittent) |
| Operating Temperature Range | See Gas Sensor Selection \& Specification Table on back of data sheet |
| Supply Voltage / Protection | +24 VDC nominal (+12 to 36 VDC Load Dependent) | 0.5A Socketed Pico Fuse |
| Terminal Block Torque Rating | 0.37 ft-lb (0.502 Nm) Nominal |
| Operating Atmospheric Pressure | 14.696 psi (1.0132 bar) +/- 10% Note: When installed @ > 3000’ above sea level, the gas transmitters must be veried for accuracy \& re-calibrated as needed after installation |
| Storage Temperature | RH Range | 32 to 68ºF (0 to 20ºC) | 15 to 90% RH, Non-Condensing |
| Coverage Area / Mounting Height | See Gas Sensor Selection \& Specification Table on back of data sheet |
| Supply Current / Power Consumption | 25 mA maximum | 0.9 Watts maximum |
| Intrinsic Safety Barrier Requirement | 28.5 VDC maximum and 300 minimum load Note: Requirements to meet when installed with CSA Approved Intrinsic Safety Barriers in Class A, B, C \& D Certified environments |
| Enclosure Specifications (Type, Material Type, Flammability, NEMA/IP Rating, Explosion Proof) | Commercial “C”: General Purpose (Wall Mount); ABS Plastic, UL94 V-0; NEMA 1 (IP10) Commercial “D”: General Purpose (Duct Mount); ABS Plastic, UL94 V-0; NEMA 1 (IP10) Commercial “N”: Weatherproof (Wall Mount); ABS Plastic; UL94 V-0; NEMA 4X (IP56) Industrial “E”: Industrial Connection Head; Aluminum (Epoxy Coated); NEMA 4X (IP56) and Enclosure meets Type 7 \& 9 Explosion Proof Class 1 Div. 1, Groups B, C, D also Group A; CSA, FM (Factory Mutual), EX (Explosion Proof), UL listed Industrial “S”: Industrial Connection Head; 316 Stainless Steel; NEMA 4X (IP56) and Enclosure meets Type 7 \& 9 Explosion Proof Class 1 Div. 1, Groups B, C, D also Group A; CSA, FM (Factory Mutual), EX (Explosion Proof), UL listed Note for E \& S enclosure: The Cl2, ClO2, HCl, SO2, NO2, NH3, and O3 sensor assemblies are NOT explosion-proof rated |
Specifications
| SKU | CS6287673 |
|---|---|
| MPN | QTS-61110X-S000000 |
| Alternate Part # | 136150 |