Hydrolevel 45-460-2060
SKU: CS6107628MPN: 45-460-2060UPC/EAN: 642277602060
CycleGard CG450-2060 Low Water Cutoff w/ 20 Minute Intermittent Level Test - 120V (Steam)






Contact us for pricing and availability
Product Details
Note: This is a direct replacement for Slant/fin 430-166-000
While continuously monitoring the water level, CycleGard adds protection against false signals created by foam and volatile water conditions. At preset intervals, CycleGard’s Intermittent Level Test removes power from the burner for 60 or 90 seconds. During this test, foam dissipates and the water level stabilizes– allowing CycleGard to monitor the true water level in the boiler assuring accurate operatio.
Product Features
- Intermittent Level Test – Maximum Protection for Foaming Boilers
- 15 Second Burner Off Delay
- 30 Second Burner On Delay
- Automatic Reset
- Low Water Indicating Light
- Direct Boiler Mounting – Eliminates Blowdowns
- Models ending in “2060” perform the ILT every 20 minutes for 60 seconds.
Specifications
- Power Consumption: 4.2 VA
- Switching Capacity: 5.8 FLA, 34.8 LRA
- Switch Contacts: SPDT
- Max Pressure: 15 PSI
Specifications
| SKU | CS6107628 |
|---|---|
| MPN | 45-460-2060 |
| UPC/EAN | 642277602060 |