Eaton 259816

SKU: CS5021057MPN: 259816UPC/EAN: 04015082598167

Eaton Moeller series NZM release

$465.67
Unit
Available on backorder
remove
add

Product Details

Eaton Moeller series NZM - Molded Case Circuit Breaker. Shunt release, 110-130VAC/DC, +1early N/O, ⅔

Attributes

10 10 Temperature Rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10 11 Short Circuit Rating Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10 12 Electromagnetic Compatibility Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10 13 Mechanical Function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10 2 2 Corrosion Resistance Meets the product standard’s requirements.
10 2 3 1 Verification Of Thermal Stability Of Enclosures Meets the product standard’s requirements.
10 2 3 2 Verification Of Resistance Of Insulating Materials To Normal Heat Meets the product standard’s requirements.
10 2 3 3 Resist Of Insul Mat To Abnormal Heat Fire By Internal Elect Effects Meets the product standard’s requirements.
10 2 4 Resistance To Ultra Violet Uv Radiation Meets the product standard’s requirements.
10 2 5 Lifting Does not apply, since the entire switchgear needs to be evaluated.
10 2 6 Mechanical Impact Does not apply, since the entire switchgear needs to be evaluated.
10 2 7 Inscriptions Meets the product standard’s requirements.
10 3 Degree Of Protection Of Assemblies Does not apply, since the entire switchgear needs to be evaluated.
10 4 Clearances And Creepage Distances Meets the product standard’s requirements.
10 5 Protection Against Electric Shock Does not apply, since the entire switchgear needs to be evaluated.
10 6 Incorporation Of Switching Devices And Components Does not apply, since the entire switchgear needs to be evaluated.
10 7 Internal Electrical Circuits And Connections Is the panel builder’s responsibility.
10 8 Connections For External Conductors Is the panel builder’s responsibility.
10 9 2 Power Frequency Electric Strength Is the panel builder’s responsibility.
10 9 3 Impulse Withstand Voltage Is the panel builder’s responsibility.
10 9 4 Testing Of Enclosures Made Of Insulating Material Is the panel builder’s responsibility.
Connection Type With bolt connection
Electric Connection Type Screw connection
Fitted With Early-make auxiliary contact
Frame NZM⅔
Frequency Rating 50 Hz / 60 Hz / 200 Hz / 400 Hz, DC (shunt release)
Minimum Command Time Max 15 C26
Minimum Command Time Max Uom C26
Minimum Command Time Min 10 C26
Minimum Command Time Min Uom C26
Number Of Contacts Change Over Contacts 0.0000
Number Of Contacts Normally Closed Contacts 0.0000
Number Of Contacts Normally Open Contacts 1.0000
Pick Up Power Consumption Shunt Release 2.5 VA/W
Rated Control Supply Voltage 110 - 130 V AC/DC
Rated Control Supply Voltage Us At Ac 50 Hz Max 130 VLT
Rated Control Supply Voltage Us At Ac 50 Hz Max Uom VLT
Rated Control Supply Voltage Us At Ac 50 Hz Min 110 VLT
Rated Control Supply Voltage Us At Ac 50 Hz Min Uom VLT
Rated Control Supply Voltage Us At Ac 60 Hz Max 130 VLT
Rated Control Supply Voltage Us At Ac 60 Hz Max Uom VLT
Rated Control Supply Voltage Us At Ac 60 Hz Min 110 VLT
Rated Control Supply Voltage Us At Ac 60 Hz Min Uom VLT
Rated Control Supply Voltage Us At Dc Max 130 VLT
Rated Control Supply Voltage Us At Dc Max Uom VLT
Rated Control Supply Voltage Us At Dc Min 110 VLT
Rated Control Supply Voltage Us At Dc Min Uom VLT
Rated Control Voltage Relay Contacts 110 V DC 130 V AC 110 V AC 130 V DC
Reaction Time 20 C26
Reaction Time Uom C26
Special Features Cannot be used in conjunction with NZM…-XR… remote operator. If the shunt trip is live, contact with the circuit breaker’s primary contacts is prevented when switched on. Early make of auxiliary contact on switching on and off (manual operation): approx. 20 ms. Shunt releases cannot be installed simultaneously with NZM…-XHIV… early-make auxiliary contact or NZM…-XU… undervoltage release.
Suitable For Off-load switch
Terminal Capacity Solid Flexible Conductor 18 - 14 AWG (2x) at shunt release 0.75 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule 0.75 mm² - 2.5 mm² (1x) at shunt release with ferrule 18 - 14 AWG (2x) for undervoltage releases, off-delayed 0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule 18 - 14 AWG (1x) for undervoltage releases, off-delayed 0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule 18 - 14 AWG (1x) at shunt release
Time On Duty Max
Type Accessory Shunt release
Undelayed Short Circuit Release Max 0 AMP
Undelayed Short Circuit Release Max Uom AMP
Undelayed Short Circuit Release Min 0 AMP
Undelayed Short Circuit Release Min Uom AMP
Used With NZM3(-4), N(S)3(-4) NZM2(-4), N(S)2(-4)
Voltage Rating 0.7 - 1.1 x Us
Voltage Rating At Ac X Us Max 1.1000000238419
Voltage Rating At Ac X Us Min 0.69999998807907
Voltage Rating Uom VLT
Voltage Type AC

Specifications

SKUCS5021057
MPN259816
UPC/EAN04015082598167