Multi-Parameter Input Transmitter

$1,908.54
Unit
Available on backorder
remove
add

Product Details

  • Large Auto-Sensing Backlit Display
  • “Dial-Style” Digital Bar Graph
  • Intuitive and “User-Friendly” Interface
  • Optional Field Upgradable Relays

Attributes

Keypad 4 buttons, injection-molded silicone rubber seal
Weight 0.63 kg
Accuracy ± 0.5 %
Mounting Specified to Omega field mount junction boxes
Frequency 0.5 to 1500 Hz
Series ID DPU91-Series
Input Note Digital Serial: ACSII, TTL level, 9600 bps Frequency Input: Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency Span: 0.5 Hz to 1500 Hz @ TTL level input
Input Type Pulse, S3L
Resolution 1 μS
Wire Gauge 14 AWG
Form factor ¼ DIN
Update Rate 1 sec
Altitude,Max 4000 m
Control Mode Batch Control
Display Note LCD Contrast: 5 settings
Display Type Backlit LCD
Output Detail 4 to 20 mA (10.8 to 35.2 Vdc, 30 mA maximum)
Repeatability ±0.2% of reading
LED Indicators “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator
Sensor Voltage 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected
Supply Voltage 10.8 to 35.2 Vdc
Accuracy Detail ± 0.5% or reading maximum error @ 25°C (77ºF)
Input Type Note Digital or AC Frequency: pH/ORP input via the digital output from the PHTX-2750 pH/ORP sensor electronics Conductivity/Resistivity: Input directly from OMEGA conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850
Measurement Type Flow, pH, ORP, conductivity, salinity, pressure, temperature, batch
Country of Origin United States
Display Type Note Backlit, 7 and 14-segment LCD
Electrical Output 4 to 20 mA
Enclosure Ratings IP65, NEMA Type 4X
Relative Humidity 0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount
Supply Power Note DPU91 without Relay Module: 200 mA @ 10.8 to 35.2 Vdc DPU91 with Relay Module: 300 mA @ 10.8 to 35.2 Vdc
Enclosure Material PBT
Number of Channels 1
Flow Indication Note Flow Rate: -9999 to 99999 units per second, minute, hour or day Totalizer: 0.00 to 99999999 units (program lockout or resettable)
Mounting Orientation Field Mount
PH Measurement Range 0 to 15 pH
Additional Features 1 Field Mount, Sensors
Electrical Connection Screw Terminal
ORP Measurement Range -1999 to 1999.9 mV
Control Characteristics Dry-Contact Relays: 2 Open Collector: 1 Type: SPDT N/A Form C: N/A Maximum Current Rating: 5 A resistive 50 mA DC Maximum Voltage Rating: 30 Vdc or 250 Vac Hysteresis Adjustable: Absolute in engineering units (EUs) Latch Reset: In test screen only Delay: 9999.9 seconds (maximum) Test Mode: Set on/off Cycle Time: 99999 seconds (maximum) Maximum Pulse Rate: 400 pulses/minute Proportional Pulse: 400 pulses/minute Volumetric Pulse Width: 0.1 to 3200 s Pulse Width Modulation: 0.1 to 320 s
Display Measuring Units kΩ, MΩ, ms, ppb, ppm, μS
Over-Voltage Protection 48 V transient protection device current limiting for circuit protection and reverse-voltage protection
Conductivity Measurement 0.0000 to 99999 μS
Storage Temperature, Max 70 °C
Storage Temperature, Min -15 °C

Specifications

SKUCS6002775
MPNDPU91-BC