Eaton 167119

SKU: CS5019793MPN: 167119UPC/EAN: 04015081636211

Eaton Moeller series xEffect - FRCmM-NA RCCB

Contact us for pricing and availability

Product Details

Eaton Moeller series xEffect - FRCmM-NA RCCB. Residual current circuit breaker (RCCB), 25A, 2p, 30mA, type G/A, UL

Attributes

10 10 Temperature Rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10 11 Short Circuit Rating Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10 12 Electromagnetic Compatibility Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10 13 Mechanical Function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10 2 2 Corrosion Resistance Meets the product standard’s requirements.
10 2 3 1 Verification Of Thermal Stability Of Enclosures Meets the product standard’s requirements.
10 2 3 2 Verification Of Resistance Of Insulating Materials To Normal Heat Meets the product standard’s requirements.
10 2 3 3 Resist Of Insul Mat To Abnormal Heat Fire By Internal Elect Effects Meets the product standard’s requirements.
10 2 4 Resistance To Ultra Violet Uv Radiation Meets the product standard’s requirements.
10 2 5 Lifting Does not apply, since the entire switchgear needs to be evaluated.
10 2 6 Mechanical Impact Does not apply, since the entire switchgear needs to be evaluated.
10 2 7 Inscriptions Meets the product standard’s requirements.
10 3 Degree Of Protection Of Assemblies Does not apply, since the entire switchgear needs to be evaluated.
10 4 Clearances And Creepage Distances Meets the product standard’s requirements.
10 5 Protection Against Electric Shock Does not apply, since the entire switchgear needs to be evaluated.
10 6 Incorporation Of Switching Devices And Components Does not apply, since the entire switchgear needs to be evaluated.
10 7 Internal Electrical Circuits And Connections Is the panel builder’s responsibility.
10 8 Connections For External Conductors Is the panel builder’s responsibility.
10 9 2 Power Frequency Electric Strength Is the panel builder’s responsibility.
10 9 3 Impulse Withstand Voltage Is the panel builder’s responsibility.
10 9 4 Testing Of Enclosures Made Of Insulating Material Is the panel builder’s responsibility.
Admissible Back Up Fuse Overload Max 25 A gG/gL
Ambient Humdity Range 5 - 95 %
Ambient Operating Temperature Max 40 CEL
Ambient Operating Temperature Max Uom CEL
Ambient Operating Temperature Min -25 CEL
Ambient Operating Temperature Min Uom CEL
Amperage Rating 25 A
Application Switchgear for export to North America (UL-listed)
Climatic Proofing 25-55 °C / 90-95% relative humidity according to IEC 60068-2
Connectable Conductor Cross Section Multi Wired Max 16 MMK
Connectable Conductor Cross Section Multi Wired Max Uom MMK
Connectable Conductor Cross Section Multi Wired Min 1.5 MMK
Connectable Conductor Cross Section Multi Wired Min Uom MMK
Connectable Conductor Cross Section Solid Core Max 35 MMK
Connectable Conductor Cross Section Solid Core Max Uom MMK
Connectable Conductor Cross Section Solid Core Min 1.5 MMK
Connectable Conductor Cross Section Solid Core Min Uom MMK
Contact Position Indicator Color Red / green
Degree Of Protection IP20, IP40 with suitable enclosure IP20
Equipment Heat Dissipation Current Dependent 2 W
Fault Current Rating 30 4K
Fault Current Rating Uom 4K
Features Additional equipment possible Residual current circuit breaker
Fitted With Interlocking device
Frame 45 mm
Frequency Rating 50 Hz / 60 Hz
Functions Short-time delayed tripping
Heat Dissipation Capacity 0 WTT
Heat Dissipation Capacity Uom WTT
Heat Dissipation Per Pole Current Dependent 1 WTT
Heat Dissipation Per Pole Current Dependent Uom WTT
Impulse Withstand Current 3 kA (8/20 μs) surge-proof
Leakage Current Type A
Lifespan Electrical 4000 operations
Lifespan Mechanical 10000 operations
Mounting Method Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715 DIN rail
Mounting Position As required
Number Of Poles Two-pole
Overvoltage Tested Max 530 VLT
Overvoltage Tested Max Uom VLT
Permitted Storage And Transport Temperature Max 60 CEL
Permitted Storage And Transport Temperature Max Uom CEL
Permitted Storage And Transport Temperature Min -35 CEL
Permitted Storage And Transport Temperature Min Uom CEL
Pick Up Current 22 mA
Pollution Degree 2.0000
Ral Number 7035.0000
Rated Fault Current Max 0.03 AMP
Rated Fault Current Max Uom AMP
Rated Fault Current Min 0.03 AMP
Rated Fault Current Min Uom AMP
Rated Impulse Withstand Voltage Uimp 4 kV
Rated Insulation Voltage Ui 440 VLT
Rated Insulation Voltage Ui Uom VLT
Rated Operational Current For Specified Heat Dissipation In 25 AMP
Rated Operational Current For Specified Heat Dissipation In Uom AMP
Rated Operational Voltage Ue Max 277 VLT
Rated Operational Voltage Ue Max Uom VLT
Rated Residual Making And Breaking Capacity 500 AMP
Rated Residual Making And Breaking Capacity Uom AMP
Rated Short Circuit Strength 5 kA (UL, as per CSA) 10 kA with back-up fuse
Rated Short Time Withstand Current Icw 10 kA
Sensitivity Type Pulse-current sensitive
Short Circuit Rating Max. admissible back-up fuse: 63 A gG/gL, 70 A class J fuse (UL)
Short Circuit Rating Uom WTT
Special Features FRCmM-NA Residual current circuit breakers Type G/A (ÖVE E 8601)
Static Heat Dissipation Non Current Dependent 0 WTT
Static Heat Dissipation Non Current Dependent Uom WTT
Status Indication White / blue
Surge Current Capacity 3 B22
Surge Current Capacity Uom B22
Terminal Capacity Cable M5 (with cross-recessed screw as defined in EN ISO 4757-Z2, PZ2)
Terminal Capacity Solid Wire 1.5 mm² - 35 mm²
Terminal Capacity Stranded Cable 16 mm² (2x)
Terminal Protection Finger and hand touch safe, DGUV VS3, EN 50274
Terminals Top And Bottom Lift terminals
Test Circuit Range 184 V AC - 250 V AC, 196 V AC - 305 V AC (UL)
Tripping Time Short time-delayed 10 ms delay at 50 Hz 8 ms delay at 60 Hz
Type Current test marks as per inscription Maximum operating temperature is 55 °C: Starting at 40 °C, the max. permissible continuous current decreases by 3% for every 1 °C The maximum operating current of back-up fuse must not exceed the residual current circuit breaker’s rated operational current
Used With Type G/A (�VE E 8601) FRCmM-NA Residual current circuit breakers
Voltage Rating Iec En 60947 2 240 V AC / 415 V AC
Voltage Rating Ul 480Y/277 V, 60 Hz
Voltage Type AC