ACI Q8-NO2-10P-O-X
SKU: CS6288950MPN: Q8-NO2-10P-O-XAlternate Part #: 143028
Expl Proof, Smart Sensor, Nitrogen Dioxide, 0-10 ppm, 3 SPDT Relays, NEMA 4X, 4-20mA, 2-10V, or Modbus RTU

Contact us for pricing and availability
Product Details
Expl Proof, Smart Sensor, Nitrogen Dioxide, 0-10 ppm, 3 SPDT Relays, NEMA 4X, 4-20mA, 2-10V, or Modbus RTU
Product Configuration
| Series | Q8 Explosion Proof Gas Sensor |
|---|---|
| Gas Type | Nitrogen Dioxide |
| Configuration Modification | None |
Product Family Specifications
| Keypad | Three (Non-Intrusive) Magnetic Switches |
|---|---|
| Display | LCD Graphic Display with backlight (Displays TWA, STEL and PEAK Daily Value) |
| Gas Types | Combustible and Toxic Gases/Oxygen Sensor |
| Sensor Type | See Sensor Technology Type in Table on back of Product Data Sheet |
| Warm Up Time | 24 Hours (Allow 24 hours before calibrating sensor after initial installation) |
| Analog Outputs | Q8 Only: 4-20 mA, 1-5 VDC or 2-10 VDC (4-Wire Power, Power Ground, Output Signal, Output Signal Common) |
| Product Weight | 4.35 lbs. (1.973 kg) |
| Supply Voltage | Q8: VDC Supply Voltage: 24 VDC nominal (+18 to 30 VDC) (Q8: AC Power must not be grounded) Q8: VAC Supply Voltage: 24 VAC nominal (+15 to 24 VAC, AC Power must not be grounded) B8: VDC Supply Voltage: 24 VDC nominal (+18 to 30 VDC) (AC Power can be grounded or non-grounded) B8: VAC Supply Voltage: 24 VAC nominal (+15 to 24 VAC, AC Power must not be grounded) |
| Fuse Protection | 0.750A Polyswitch; (Automatically resets after fault is cleared \& power to circuit is removed) |
| Life Expectancy | Electrochemical (Toxic): 2 to 3 Years, typical Oxygen/Hydrogen (Toxic): 18 months, typical Catalytic (Combustible): 3 to 5 years, typical |
| Unit Shelf Life | Electrochemical (Toxic): 6 Months from date of purchase (Must be installed and operational) Catalytic (Combustible): 1 Year from date of purchase (Must be installed and operational) |
| Agency Approvals | RoHS, CSA-Class 4828-02 inspected to C22.2 No. 30 and No. 142 (CSA File #: 088890_0_000) |
| Conduit Knockouts | Two ¾” NPT Threaded Openings |
| Product Dimensions | 7.48” (190 mm) x 5.71” (145 mm) x 5.12” (130 mm) |
| Replacement Sensor | See User’s Manual or Contact ACI |
| Communications Cable | Belden 9841 or Equivalent, 120 Ohms Input Impedance |
| Supported Baud Rates | Q8: 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) B8: 9600, 19200, 38400, 76800 Bits/Second (Default: 38400) |
| Operating Environment | Indoor Use only |
| Output Load Impedance | 4-20 mA Output: 600 Ohms maximum | 1-5 VDC or 2-10 VDC: 3000 Ohms minimum |
| Status LED Indication | Two Green LED’s (Tx/Rx Communication Status), Three Red LED’s (Relays 1, 2 \& 3 Status) |
| Communication Protocols | Q8 Communication Protocols: RS-485 Modbus RT/OptoMux (Proprietary QEL Communication) B8 Communication Protocols: RS-485 Serial BACnetTM MS/TP (Master and Slave; Default: Master) |
| Recommended Maintenance | Catalytic (Combustible): Accuracy \& Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy \& Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months |
| Factory Calibrated Ranges | See Gas Sensor Selection \& Specification Table on back of data sheet |
| Factory Calibration Range | See Gas Sensor Selection \& Specification Table on back of data sheet |
| Operating Temperature / RH | See Sensor Selection \& Specification Table on back of data sheet | 5 to 95% RH, non-condensing |
| Terminal Block Torque Rating | 0.37 ft-lb (0.502 Nm) Nominal |
| Operating Atmospheric Pressure | 14.696 psi (1.0132 bar) +/- 10% Note: When installed @ >3000’ above sea level, the gas transmitters must be verified for accuracy \& re-calibrated as needed after installation |
| Storage Temperature | RH Range | 32 to 68°F (0 to 20°C) | 5 to 95% RH, non-condensing |
| Wiring Connections / Wire Size | Depluggable Screw Terminal Blocks | 16 to 24 AWG (0.51 to 1.30 mm) Shielded Twisted Pair |
| Coverage Area / Mounting Height | See Gas Sensor Selection \& Specification Table on back of data sheet |
| Supply Current / Power Consumption | 0.3A maximum | 8.4 VA |
| Relays / Contact Type / Relay Contact Ratings | Three, SPDT (Form 1C) Dry Contact rated 1.0A max. @ 30 VDC or 0.3A max. @ 125 VAC (Resistive Load) |
| Enclosure Specifications (Type, Material Type, Flammability, NEMA/IP Rating, Explosion Proof) | Industrial Connection Head; Cast Aluminum Epoxy Coated NEMA 4X (IP66), Division 1 Division 2, ANSI/ISA 12.22.01 Class I, Zone 1, AEx d II C, IP66 Zone 1 CSA E60079-1 Ex d II C, Class I, Zone I, IP 66 CSA C22.2 No. 30 Class I, Groups A, B, C, D; Class II Groups E, F, G; Class III |
Specifications
| SKU | CS6288950 |
|---|---|
| MPN | Q8-NO2-10P-O-X |
| Alternate Part # | 143028 |