ACI B5-CL2-5P-O-X

SKU: CS6287562MPN: B5-CL2-5P-O-XAlternate Part #: 135328

BACnet MSTP, Smart Sensor, Chlorine, 0-5 ppm, 3 SPDT Relays, NEMA 4X

Contact us for pricing and availability

Product Details

BACnet MSTP, Smart Sensor, Chlorine, 0-5 ppm, 3 SPDT Relays, NEMA 4X

Product Configuration

Series B5 (BACnet Protocol)
Gas Type Chlorine

Product Family Specifications

Buzzer 80 dB at 3.94” (10 cm), 2700 Hz (3 Programmable Tones)
Keypad Three Capacitive Touch sensing keys
Display LCD Graphic Display with backlight (Displays: TWA, STEL and Concentration)
Sensor Life Toxic/Electrochemical Sensors: 2 to 3 Years, typical; Oxygen/Hydrogen Sensors: 18 months, typical Combustible/Catalytic: 3 to 5 years, typical; CO 7 years, typical
Sensor Type See Sensor Technology Type in Table on back of Product Data Sheet
Warm Up Time 24 Hours (Allow 24 hours before calibrating sensor after installation)
Analog Outputs Q5 ONLY: Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires)
Product Weight 1.00 lbs. (0454 kg)
Supply Voltage Q5: VDC Supply Voltage: 24 VDC nominal (+18 to 30 VDC) (AC Power must not be grounded) Q5: VAC Supply Voltage: 24 VAC nominal (+15 to 24 VAC, AC Power must not be grounded) B5: VDC Supply Voltage: 24 VDC nominal (+18 to 30 VDC) (AC Power can be grounded or non-grounded) B5: VAC Supply Voltage: 24 VAC nominal (+15 to 24 VAC, AC Power must not be grounded)
Fuse Protection 0.750A Polyswitch; (Resets after fault is cleared \& power to circuit is removed)
Unit Shelf Life Electrochemical (Toxic) Sensors: 6 months from date of purchase Catalytic (Combustible) Sensors: 1 year from date of purchase
Agency Approvals RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control \& Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO \& B5C-CO only: UL 2075 Gas \& Vapor Detectors \& Sensors (ETL Control# 4010204)
Sensor Gas Types Combustible, Toxic Gases/Oxygen Sensor \& Infrared
Product Dimensions 5.91” (150 mm) x 3.54” (90 mm) x 2.56” (65 mm)
Enclosure Knockouts ¾” Knockouts (accepts ½” Conduit Fittings)
Communications Cable Belden 9841 or Equivalent, 120 Ohms Input Impedance
Supported Baud Rates Q5: 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) B5: 9600, 19200, 38400, 76800 Bits/Second (Default: 38400)
Operating Environment Indoor Environment only
Relay Life Expectancy Mechanical: 50,000,000 operations minimum @ 36,000 operations/hour Electrical: 200,000 operations minimum @ rated load
Status LED Indication Two Green LEDs (Tx/Rx Communication Status); Three Red LEDs (Relays 1, 2, \& 3)
Communication Protocols Q5 Communication Protocols: RS-485 Modbus RTU / OptoMux (Proprietary QEL Controller Protocol) B5 Communication Protocols: RS-485 Serial BACnet MS/TP (Master and Slave; Default: Master)
Connections | Wire Size De-pluggable Screw Terminal Blocks | 16 to 24 AWG (0.2047 to 1.301 mm) Shielded Twisted Pair
Maximum Load Resistance Q5 ONLY: 4-20 mA Output: 600 Ohms maximum | 1-5 VDC or 2-10 VDC: 3000 Ohms minimum
Recommended Maintenance Combustible Sensors: Accuracy \& Bump test every 3 months or as required by Code Toxic Sensors: Accuracy \& Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months
Factory Calibration Range See Gas Sensor Selection \& Specification Table on back of data sheet
Operating Temperature / RH See Sensor Selection \& Specification Table on back of data sheet | 5 to 95% RH, non-condensing
Replacement Sensor Modules See additional on-line Product Literature or Contact ACI
Terminal Block Torque Rating 0.37 ft-lb (0.502 Nm) Nominal
Operating Atmospheric Pressure 14.696 psi (1.0132 bar) +/- 10% Note: When installed @ > 3000’ above sea level, the gas transmitters must be verified for accuracy \& re-calibrated as needed after installation
Storage Temperature | RH Range 32 to 68°F (0 to 20°C) | 5 to 95% RH, non-condensing
Coverage Area / Mounting Height See Gas Sensor Selection \& Specification Table on back of data sheet
Supply Current / Power Consumption 0.3A maximum | 8.4 VA
Relays / Contact Type / Relay Contact Ratings Three | SPDT (Form C) Dry Contacts | 1.0A max. @ 30 VDC or 0.3A max. @ 125 VAC (Resistive Loads)
Enclosure Specifications (Material, Flammability, Temperature, NEMA/IP Rating) Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66)

Specifications

SKUCS6287562
MPNB5-CL2-5P-O-X
Alternate Part #135328