ACI QIRF-R410AX-0
SKU: CS6287139MPN: QIRF-R410AX-0Alternate Part #: 131606
Refrigerant Sensor, R410a, 0-1000 PPM, LCD, 3 SPDT Relays, NEMA 4X

Contact us for pricing and availability
Product Details
Refrigerant Sensor, R410a, 0-1000 PPM, LCD, 3 SPDT Relays, NEMA 4X
Product Configuration
| Gas Type | R410A |
|---|
Product Family Specifications
| Buzzer | 80 dB at 3.94” (10 cm), 2700 Hz (3 Programmable Tones) |
|---|---|
| Keypad | Four Magnetic Sensors with Magnetic Tool |
| Display | 2 x 8 Character Display with backlight |
| Accuracy | +/-3% of Reading |
| Sensor Life | 14 Years, typical |
| Sensor Type | Infrared, Temperature Controlled |
| Warm Up Time | 60 Minutes |
| Repeatability | +/-1% of Full Scale |
| Response Time | \<30 seconds for 90% step change |
| Analog Outputs | 4-20 mA (4-wires) or 2 to 10 VDC (4-wires) |
| Product Weight | 2.50 lbs (1.134 kg) |
| Supply Voltage | VDC Supply Voltage: 24 VDC nominal (+18 to 30 VDC) VAC Supply Voltage: 24 VAC nominal, 50/60 Hz (+15 to 24 VAC, AC Power must not be grounded) |
| Fuse Protection | Resettable: F1 on Display Board: 1.6 A Resettable: F2 on Display Board: 50 mA (Resets once fault is cleared \& power is removed) |
| Agency Approvals | RoHS |
| Refrigerant Types | R11, R12, R22, R23, R32, R114, R116, R123, R134A, R141B, R402A, R404A, R407A, R407B, R407C, R407D, R407E, R407F, R408A, R409A, R410A, R422A, R438A, R448A, R449A, R452A, R453A, R507A, R508B, R513A, R514A, R1233ZD, R1234ZE |
| Product Dimensions | 7.87” (200 mm) x 4.72” (120 mm) x 3.54” (90 mm) |
| Enclosure Knockouts | ⅞” Knockout (accepts ½” Conduit Fitting); Quantity: 1 |
| Communications Cable | Belden 9841 or Equivalent, 120 Ohms Input Impedance |
| Supported Baud Rates | 1200, 2400, 4800,9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800 BPS) |
| Operating Environment | Indoor Environment only |
| Output Load Impedance | 4-20 mA Output: 600 Ohms maximum | 2-10 VDC Output: 3000 Ohms minimum |
| Relay Life Expectancy | Mechanical: 50,000,000 operations minimum @ 36,000 operations/hour Electrical: 200,000 operations minimum @ rated load |
| Status LED Indication | Two Green LED’s (Tx/Rx Communication Status); Three Red LED’s (Relays 1, 2 \& 3) |
| Communication Protocols | Modbus RTU / OptoMux (Proprietary Gas Controller Protocol for Q4C, M-Con. \& Q-Con. only) |
| Recommended Maintenance | Accuracy \& Bump Test once per year or as required by Code |
| Factory Calibration Range | 0 to 1000 ppm for all standard Refrigerants except R123 (0 to 100 ppm); Others available |
| Operating Temperature / RH | -49 to 149°F (-45 to 65°C) | 5 to 95% RH, non-condensing |
| Operating Atmospheric Pressure | 14.696 psi (1.0132 bar) +/-10% Note: When installed @ >3000’ above sea level, the refrigerant detectors must be verified for accuracy \& re-calibrated as needed after installation |
| Storage Temperature | RH Range | -49 to 158°F (-45 to 70°C) | 5 to 95% RH, non-condensing |
| Wiring Connections / Wire Size | De-pluggable Screw Terminal Blocks | 16 to 24 AWG (0.2047 to 1.301 mm) Shielded Twister Pair |
| Coverage Area / Mounting Height | 7500 ft2 (696.7 m2) or 49 ft (14.9 m) Radius | 6” (15.3 cm) to 18” (45.8 cm) above floor |
| Supply Current / Power Consumption | 1.0 A maximum | 27 VA |
| Relays / Contact Type / Relay Contact Ratings | Three | SPDT (Form C) Dry Contacts | 1.0 max. @ 30 VDC or 0.3A max. @ 125 VAC (Resistive Loads) |
| Enclosure Specifications (Material, Flammability, Temperature, NEMA/IP Rating) | Plastic Enclosure; Polycarbonate/ABS Blend; UL94 5VA; NEMA 4, 4X 12 \& 13(IP66) |
Specifications
| SKU | CS6287139 |
|---|---|
| MPN | QIRF-R410AX-0 |
| Alternate Part # | 131606 |