ACI A/TT100-I-4"-4-PB
SKU: CS6286541MPN: A/TT100-I-4"-4-PBAlternate Part #: 123437
Transmitter w/ 100 Ohm RTD, Immersion, Welded Well, 4”, Plastic Enclosure, 4-20mA Output

Contact us for pricing and availability
Product Details
Transmitter w/ 100 Ohm RTD, Immersion, Welded Well, 4”, Plastic Enclosure, 4-20mA Output
Product Configuration
| Length | 4” |
|---|---|
| Sensor | TT100 (XMTR, 100 Ω) |
| Enclosure | Plastic |
| Thermowell Type | 2 Part Fabricated |
| Transmitter Output | 4-20mA |
Product Family Specifications
| Accuracy | (Tolerance Formula: +/- °C \= (0.15°C + (0.002 * |t|)) where |t| is the absolute value of temperature above or below 0°C |
|---|---|
| Stability | +/- 0.03% after 1000 Hours @ 300°C (572°F) |
| Sensor Type | Platinum RTD |
| Number Wires | Two |
| Sensor Curve | PTC (Positive Temperature Coefficient) |
| Output Signals | Current: 4-20 mA (2-Wire Loop Powered) Voltage: 1-5 VDC or 2-10 VDC (3-Wires) |
| Probe Diameter | 0.250” (6.35 mm) |
| Lead Wire Colors | A/TT100/TTM100 Series: Brown/Brown | A/TT1K/TTM1K Series: Black/Black |
| Temperature Drift | Temp. Spans \< 100°F (38°C): +/- 0.04% | Temp. Spans > 100°F (38°C): +/- 0.02% |
| Number Sensing Points | One |
| Connections | Wire Size | Screw Terminal Blocks (Polarity Sensitive) | 16 AWG (1.31 mm2) to 26 AWG (0.129 mm2) |
| Operating Humidity Range | 10 to 90% RH, non-condensing |
| Storage Temperature Range | -40 to 85°C (-40 to 185°F) |
| TT Maximum Load Resistance | (Terminal Voltage - 8.5 V) | 0.020 A |
| Operating Temperature Range | -40 to 185°F (-40 to 85°C) |
| Calibrated Temperature Spans | Minimum Temp. Span: 50°F (28°C) | Maximum Temp. Span: 500F (260°C) |
| Platinum RTD Tolerance Class | +/- 0.06% Class A |
| Sensor Output @ 0ºC (32ºF) | A/TT100/TTM100 Series: 100 Ohms nominal | A/TT1K/TTM1K Series: 1000 Ohms nominal |
| Terminal Block Torque Rating | 0.37 ft-lb (0.5 Nm) nominal |
| Warm Up Time | Warm Up Drift | 10 Minutes | +/- 0.1% |
| Response Time (63% Step Change) | 8 Seconds nominal |
| Sensor Operating Temperature Range | -40 to 200ºC (-40 to 392ºF) |
| TT Calibrated Accuracy | Linearity | Temp. Spans \< 500°F (260°C): +/- 0.2% | Temp. Spans > 500°F (260°C): +/- 0.5% |
| Thermowell Material | Bore Diameter | 0.260” (6.60mm) |
| Din Standard | Temperature Coeffcient | DIN EN 60751 (IEC 751) | 3850 ppm/°C |
| TTM100/TTM1K NIST Certification Points | 3 Point NIST: 20%, 50% \& 80% of span 5 Point NIST: 20%, 35%, 50%, 65%, 80% of span |
| Transmitter Supply Voltage | Supply Current | +8.5 to 32 VDC (Reverse Polarity Protected) | 25 mA minimum 250 Ohm Load: +13.5 to 32 VDC | 500 Ohm Load: +18.5 to 32 VDC |
| Matched Calibrated Temperature Spans (A/TTM models) Range | -45 to 155°C (-49 to 311°F) |
| Enclosure Specifications (Material, Flammability, Temperature, NEMA/IP Rating) | “-GD” Enclosure: Galvanized Steel, -40 to 121°C (-40 to 250°F), NEMA 1 (IP10) “-PB” Enclosure: -30 to 100ºC (-22 to 212ºF), ABS Plastic, UL94-5VB, Plenum Rated “-BB” Enclosure: Aluminum, -40 to 121°C (-40 to 250°F), NEMA 3R “-4X” Enclosure: Polystyrene Plastic, -40 to 70°C (-40 to 158°F), UL94-V2, NEMA 4X (IP 66) |
Specifications
| SKU | CS6286541 |
|---|---|
| MPN | A/TT100-I-4"-4-PB |
| Alternate Part # | 123437 |