ACI A/RH3-D-BB
SKU: CS6286461MPN: A/RH3-D-BBAlternate Part #: 122931
Relative Humidity, RH Outputs: 0-5, 0-10 VDC \& 4-20mA (Default), Duct, ± 3% Accuracy, NEMA 3R Enclosure

Contact us for pricing and availability
Product Details
Relative Humidity, RH Outputs: 0-5, 0-10 VDC \& 4-20mA (Default), Duct, ± 3% Accuracy, NEMA 3R Enclosure
Product Configuration
| Length | 7.20” |
|---|---|
| Enclosure | NEMA 3R |
| Accuracy (Humidity) | +/-3% |
Product Family Specifications
| Output Signals | 2-wire: 4 - 20 mA (Factory Default) 3-wire: 0-5 or 0-10 VDC and 4 - 20 mA (Field Selectable) |
|---|---|
| Product Weight | A/RHx-D Series: 1.22 lbs. (0.55 kg) A/RHx-D-4X Series: 0.50 lbs. (0.227 kg) A/RHx-D-BB Series: 0.90 lbs. (0.41 kg) |
| RH Sensor Type | Capacitive with Hydrophobic Filter |
| Supply Current | Voltage Output: 8 mA maximum (0.32 VA) Current Output: 24 mA maximum (0.83 VA) |
| Supply Voltage | 4-20 mA: 250 Ohm Load: 15 - 40 VDC / 18 - 28 VAC | 500 Ohm Load: 18 - 40 VDC / 18 - 28 VAC 0-5 VDC: 12 - 40 VDC / 18 - 28 VAC | 0-10 VDC: 18 - 40 VDC / 18 - 28 VAC |
| Agency Approvals | CE, RoHS2, WEEE |
| NIST Test Points | Default Test Points: 3 Points (20%, 50% \& 80%) 1% NIST Test Points: 5 Points within selected 20% Range (ie. 30%-50% are 30, 35, 40, 45 \& 50) |
| RH Measurement Range | 0-100% |
| Output Load Resistance | 4-20 mA: 700 Ohms maximum 0-5 VDC or 0-10 VDC: 4K Ohms Minimum |
| Connections | Wire Size | Screw Terminal Blocks (Polarity Sensitive) | 16 (1.31 mm²) to 26 AWG (0.129 mm²) |
| Accuracy @ 77°F (25°C) | Model Dependent: +/- 1% over 20% RH Range between 20 to 90% | +/- 2%, or 3% from 10 to 95% |
| Operating Humidity Range | 0 to 95% RH, non-condensing (Conformally Coated PCB’s) |
| Storage Temperature Range | -40 to 149°F (-40 to 65°C) |
| Operating Temperature Range | -40 to 140°F (-40 to 60°C) |
| Terminal Block Torque Rating | 4.43 to 5.31 lb-in (0.5 to 0.6 Nm) |
| Response Time (63% Step Change) | 20 Seconds Typical |
| RH Transmitter Stabilization Time | 30 Minutes (Recommended time before doing accuracy verification) |
| Sensing Tube Material | Filter Material | “EH” Enclosure: 304 Series Stainless Steel | 304 Series Stainless Steel “-4X” Enclosure: Schedule 40 PVC (White) | Slotted PVC without filter “-BB” Enclosure: Schedule 40 PVC (White) | Slotted PVC without filter |
| RH Stability | Repeatability | Sensitivity | Less than 2% drift / 5 years | 0.5% RH | 0.1% RH |
| Sensing Tube Dimensions (Length x Diameter) | “-EH” Models with Sintered Filters: 7.75” (196.85 mm) x 0.75” (19.05 mm) “-4X” Models: 7.20” (182.88 mm) x 0.840” (21.34 mm) “-BB” Enclosure: 7.20” (182.88 mm) x 0.840” (21.34 mm) |
| Enclosure Specifications (Material, Flammability, Temperature, NEMA/IP Rating) | “-EH” Enclosure: ABS Plastic | UL94-V0 | -40 to 140°F (-40 to 60°C) “-4X” Enclosure: Polystyrene Plastic | UL94-V2 | -40 to 158°F (-40 to 70°C) | NEMA 4X (IP 66) “-BB” Enclosure: Aluminum | -40 to 140°F (-40 to 60°C) |
Specifications
| SKU | CS6286461 |
|---|---|
| MPN | A/RH3-D-BB |
| Alternate Part # | 122931 |