// 500+ Brands

// Authorized Distributor of Over 100 Brands

menu

Omega ILD44-UTP-C4EI

SKU: CS5803945MPN: ILD44-UTP-C4EI

Large Display Meters \& PID Controllers, Color Changing Display

$2,405.06
Unit
Available on backorder
remove
add

Product Details

  • UL and cUL Certified
  • BIG Bright 2.25’(57.2 mm) or 4.00’(101.6 mm) LED Display
  • Program to Change Colors: RED, AMBER, GREEN
  • Temperature and Process Input Models

Attributes

Accuracy ± 0.5 °C
Polarity Unipolar
RTD Type 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; α= 0.00385 or 0.00392
Isolation Power to Input/Output: 2300 Vac per 1 min test (RS232/485, input or output) Between Inputs: 500 Vac per 1 min test
Series ID iLD-Series
Input Type Themocouple, RTD, Current, Voltage
Resolution 1°/0.1°; 10 µV process
Alarm modes Band, High/Low, Latch/Unlatch, Normally Open/Closed, Process/Deviation
Control Mode Reverse (heat) or direct (cool)
Display Size 57.2 mm (2.25 in)
Display Type 4 Digit, 7 Segment LED
Reading Rate 3 samples/sec
Display Color Red, Green, Amber
Step Response 0.7 sec for 99.9%
A/D Conversion Dual slope
Data Interface Ethernet, RS485, RS422
Digital Filter Programmable
Supply Voltage 100 to 240 Vac
Accuracy Detail ±0.5°C temperature; 0.03% rdg
Impedance Input 10 MΩ for 100 mV, 1 MΩ for 1 or 10 Vdc
Span Adjustment 0.001 to 9999 counts, programmable
Country of Origin Mexico
Decimal Selection 0, 0,001, 0,01, 0,1
Display Type Note 4-digit or 6-digit, 7-segment LED 57.2 mm (2.25”) or 101.6 mm (4.00”) red, green and amber programmable colors for process variable, set point and temperature units
Enclosure Ratings IP65, NEMA Type 4
Offset Adjustment -1999 to +9999
Power Consumption 22.5 W
Relative Humidity 90% RH non-condensing
Supply Power Note 100 to 240 Vac ±10%, 50/60 Hz
Thermocouple Type J, K, T, E, N, R, S, B, C, L
Data Interface Note Ethernet : Standards compliance IEEE 802.3 10Base-T Supported Protocols : TCP/IP, ARP, HTTPGET RS232/RS422/RS485/MODBUS : Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status. RS485 : Screw terminals
Input Configuration Single-ended
Set Point Adjustment -1999 to 9999 counts
Common Mode Rejection 120 dB
Electrical Connection Screw Terminal
Normal Mode Rejection 60 dB
Temperature Stability RTD: 0.04°C/°C;Thermcouple @ 25°C (77°F): 0.05°C/°C—cold junction
Excitation Voltage Note Optional in Place of Communication
Sensor/Transmitter Power 24 Vdc @ 25 mA
Current Measurement Range 0 to 20 mA
Voltage Measurement Range 0 to 100 mV, 0 to 1 V, 0 to 10 Vdc
Warm-Up to Rated Accuracy 60 min
Operating Temperature, Max 40 °C
Operating Temperature, Min 0 °C
Thermocouple Lead Resistance, Max 100 Ω

Specifications

SKUCS5803945
MPNILD44-UTP-C4EI