Intrinsically safe differential pressure transmitter, range -1.0/+1.0” w.c.
Attributes
| Accuracy | ±0.5% at 77°F (25°C) including hysteresis and repeatability (after 1 hour warm-up). |
| Commodity Code | 0412 |
| Compensated Temperature Limits | 32 to 140°F (0 to 60°C). |
| Compliance | CE: CENELEC EN 61326/55024: 2003; IEC 61000-4-⅔/4/6: 2001/2006/2004/2005; CENELEC EN 55011: 2006; 2004/108/EC EMC Directive; FM Intrinsically Safe CLI Div I GR: A, B, C, D; CLII Div I GR: E, F, G; CLIII Div I. |
| Display | 4 digit LCD 0.6” height. |
| Electrical Connection | M-12 4 PIN Connector. |
| Enclosure Rating | Designed to meet NEMA 4X (IP66). |
| Housing Material | Aluminum, glass. |
| Mounting Orientation | Mount unit in vertical plane. |
| Output Signal | 4 to 20 mA DC. |
| Power Requirement | 10 to 35 VDC. |
| Pressure Limit | Ranges x0089¤ 2.5 in w.c.: 2 psi; 5 in w.c.: 5 psi; 10 in w.c.: 5 psi; 25 in w.c.: 5 psi; 50 in w.c.: 5 psi; 100 in w.c.: 9 psi. |
| Process Connection | ⅛” female NPT. |
| Response Time | 250 ms (damping set to 1). |
| Service | Air and non-combustible gases. |
| Stability | < ±1% per year. |
| Thermal Effect | 0.020%/°F (0.036/°C) from 77°F (25°C). |
| Wetted Material | Ranges 5 in w.c. and Greater: glass, PVC, silicon, alumina ceramic, epoxy, RTV, gold, aluminum, stainless steel and nickel; Ranges 1 in w.c. and Lower: stainless steel, silicone, gold, ceramic. |
| Zero Span Adjustments | Accessible via menus. |
Specifications
| SKU | CS4118775 |
|---|---|
| MPN | ISDP-014 |
| Alternate Part # | 100555-13 |