Dwyer IEFB-LN-CNDR10LCDCOM

SKU: CS4118752MPN: IEFB-LN-CNDR10LCDCOMAlternate Part #: 100782-41

IEFB-LN-CND-R10-LCD-COM

$4,933.89
Unit
Available on backorder
remove
add

Product Details

Insertion Electromagnetic energy system, 4 to 10” (100 to 250MM) pipe, 1% FS, 1” male NPT process connections, ½” female NPT, (2) 10’ (3 m) PT temperature sensors with hot-tap thermowells, BACnet or Modbus#8482; communications protocol (display selectable), LCD display

Attributes

Agency Approval BTL.
Applicable Pipe Material Most popular plastic and metal pipes; i.e. Carbon steel, SS, copper, UPVC/PVDF, galvanized steel, mild steel, and brass.
Applicable Pipe Size 4 to 36” (100 to 900 mm), model dependent. See model chart.
Btu Accuracy Per EN1434/ASTM E3137/CSA C900.1-13: High Accuracy Units: Class 2 for 2 to 20 ft/s (0.6 to 6 m/s); Standard Accuracy Units: Class 3 for 6.5 to 20 ft/s (2 to 6 m/s). **Verified at standard temperature 73.4°F (23°C) refer to listed standards for detailed accuracy formulations.
Calculator Accuracy Ec = ±[0.5 +(Delta)(Theta)min/(Delta)(Theta)] % per EN1434.
Commodity Code 8218
Conductivity >20 microsiemens.
Device Load ⅛ unit load.
Differential Temperature Accuracy Et = ±[0.5 +3*(Delta)(Theta)min/(Delta)(Theta)] % per EN1434 for differential temperature.
Display (-LCD option): 2 x 2” (50 x 50 mm) graphic LCD with backlight.
Electrical Connection Removable terminal blocks, (2) model selectable ½” female NPT conduit connection, (2) PG 16 gland or (2) PG 16 gland with 10 ft (3 m) 9 conductor 22 AWG plenum rated cables, accessory cable lengths up to 200 ft (61m) optional.
Enclosure Material Powder coated die cast aluminum.
Enclosure Rating NEMA 6P (IP68) (Non display models); NEMA 4X (IP66) (-LCD option).
Flow Sensor Accuracy High Accuracy Units: ±0.5% of reading at calibrated velocity, ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s) ±0.02 ft/s (±0.006 m/s) at < 2 ft/s (0.6 m/s); Standard Accuracy Units: ±1% FS.
Output (1) Analog: 4-20 mA, 0-5 V, 0-10 V or 2-10 V (display selectable); (1) Pulse/Frequency: 0-15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable); (2) Alarm: Empty pipe detection or minimum/maximum velocity, (display selectable) & Reverse flow output indication.
Output Impedance 4 to 20 mA: 536 Ω; 5V: 500 Ω 10V: 1.27k Ω.
Power Requirement 12-42 VDC, .25 A @ 24 VDC; 12-36 VAC.
Pressure Drop < 0.1 psi at 12 ft/s in 4” (<0.01 bar at 3.7 m/s in 100 mm) and larger pipe.
Pressure Limit 400 psi (27.6 bar) @ 100°F (37.8°C).
Process Connection Flowmeter: 1” NPT or BSPT with accessory full port ball valve options; Thermowell: (2) ½” NPT or BSPT thermowell with 1” full port ball valve options.
Range 0 to 20 ft/s (0 to 6 m/s). *For max flowrates >10 ft/s (3 m/s) order option -CC.
Relative Humidity 10 to 90% non-condensing.
Service Compatible clean or dirty non coating, conductive liquids.
Supported Baud Rate 9600, 19200, 38400, 57600, 76800, or 115200 bps (display selectable).
Temperature Accuracy Class B ±(0.30 + 0.005*t)°C per EN60751.
Temperature Compensation 140 to 220°F (60 to 104.4°C) < 2% error over ±30°F (-1.1 °C) change, 40 to 70°F (4.4 to 21.1°C) < 2% error over ±10°F (-12.2°C) change.
Temperature Resistance Matched 4 wire platinum RTD_x0080__x0099_s.
Type BACnet MS/TP or Modbus® RTU communication protocol (default disabled, display selectable).
Wetted Material Body shaft/fitting: 316 SS; Electrodes: 316 SS; Electrode cap: Polymer/polystyrene; O-ring: Silicone; Thermowells: 304 SS.

Specifications

SKUCS4118752
MPNIEFB-LN-CNDR10LCDCOM
Alternate Part #100782-41